2. DESCRIPTION OF THE APPLIANCE
2.1 General
The Atmos InterCombi wall-mounted gas boiler is designed for delivering
heat to the water of a CH system and the domestic hot water.
The air supply and flue discharge can be connected to the appliance by
means of two separate pipes or a concentric connection.
The appliance has its own wall mounting strip, but can also be fitted to
an optional wall mounting frame that allows top connections. An optional
pipe mounting bracket for use with the wall mounting strip is available.
These are supplied separately.
The Atmos InterCombi wall-mounted gas boiler has the CE quality mark
and the Gas certification labels HE (Sedbuk A), SV , NZ (Solar
compatible) and CW Class 5 (Hot water performance rating 1 to 6,
where 6 is the highest) and IP44 Protection class.
It is possible to use the appliance for hot water or for heating only. The
system that is not used does not need to be connected.
The appliance as delivered is suitable for natural gas (G20). A
conversion kit for propane (G31) can be supplied upon request.
2.2 Operation
The Atmos InterCombi wall-mounted gas heater is a modulating high
efficiency boiler. This means that the power is adjusted to the heat
demand.
In the aluminium heat exchanger two separate copper circuits have been
integrated.
Because of the separated circuits for central heating and hot water, the
heating and the hot water supply can operate independently of each
other. The hot water supply has priority over the heating. They cannot
work simultaneously.
The appliance has been provided with an electronic controller that
controls the fan with the heat demand from the heating system or the hot
water supply, opens the gas valve and ignites the burner, continuously
monitors the flame and controls it dependent on the power required.
2.3 Operating conditions
A code indicates the operating condition of the appliance on the service
display of the operating panel.
- Off
The appliance is not operating, but there is electrical power. There is no
response to any demand for hot domestic hot water or CH water. The
frost protection is active though. This means that the pump starts
running and the heat exchanger is heated when the temperature of the
heat exchanger drops to 5°C.
When the frost protection is activated, code
7 appears (heating of the
heat exchanger).